Programming Your Guard-It
TM
Autodialer
4-2 Guard-It
TM
Owner's Manual
Guard-It
TM
Programming Flow Chart
1
Input
Configuration
Select
Channel
1
Open
Select
Which#
Enter #
Sec 4.1 Sec. 4.2 Sec. 4.3
Sec. 4.4
Sec. 4.5
Sec. 4.6
Sec. 4.7
Input On/Off On On, Off
Alarm State if configured Closed is Closed, Open
for contact Input alarm
Alarm Set Points Off 0.0-99.9%, Off
if configured for
Analog Input
Telephone Numbers None Up to 60 digits
Alarm Trip Delay 2.0 sec 0.1-999.9
All Inputs (Power
Fail Delay is 5
minutes fixed)
Alarm Reset Time 1.0 hours 0.1-99.9
Ring Answer Delay 1 ring 1-20
Time Between Calls 10 min 0.1-99.9
(10-99.9) if there is only
one phone #
Dialing Delay 10 sec 1-20 sec
Tone/Pulse Dial Mode Auto Auto, Tone, Pulse
Phone Fault Monitor Off On, Off
Call Progress Control Off Off, On
Max rings before abandon 5 rings 4-20
call (When CPC is on)
PROGRAM ITEM
RANGE
Range of Values Table
DEFAULT
2
Closed
3
Off
4
Analog
5
Ana. Hi
6
Ana. Lo
2
Phone
Numbers
3
Recorded
Messages
4
General
Items
5
Status
Report
6
Program
Review
7
Ackn. Alarm
Reset
1
Alarm Trip
Delay
2
Alarm Reset
Time
3
Answer
Delay
4
Time
Between
5
Dialing
Delay
1
Review
Messages
2
Record
Messages
6
Tone/Pulse
7
Phone Fault
8
Call
Progress
CPC
On/Off
Max# of
Rings